Basler IP Fixed Dome Cameras
Users Manual for BIP2-DXXXXc-dn Models
Document Number: AW001015
Version: 07 Language: 000 (English)
Release Date: 14 April 2014
Przeglądanie stron 0
1 2 3 4 5 6 ... 127 128

Podsumowanie treści

Strona 1 - Basler IP Fixed Dome Cameras

Basler IP Fixed Dome CamerasUser’s Manual for BIP2-DXXXXc-dn ModelsDocument Number: AW001015Version: 07 Language: 000 (English)Release Date: 14 April

Strona 2

Accessing the Camera AW001015070006 Basler IP Fixed Dome Cameras

Strona 3 - Table of Contents

Day/Night Functionality AW0010150700096 Basler IP Fixed Dome CamerasIR-Cut Filter Modes of OperationThe IR-cut filter mechanism in the camera has seve

Strona 4

AW00101507000 Day/Night FunctionalityBasler IP Fixed Dome Cameras 97auto controls from mistakenly sensing a momentary change in lighting conditions as

Strona 5 - 1 Introduction

Day/Night Functionality AW0010150700098 Basler IP Fixed Dome Cameras6.2 IR-Cut Filter Control OptionsControlling the IR-Cut Filter Position Via a Digi

Strona 6 - 1.2 Precautions

AW00101507000 Day/Night FunctionalityBasler IP Fixed Dome Cameras 99Fig. 16: Input Used to Control IR-Cut Filter PositionIlluminatorInternal switch as

Strona 7 - 1.3 Overview

Day/Night Functionality AW00101507000100 Basler IP Fixed Dome CamerasControlling an External Device Based on the IR-Cut Filter PositionAs mentioned on

Strona 8

AW00101507000 Day/Night FunctionalityBasler IP Fixed Dome Cameras 101Fig. 17: Output Used to Apply Device PowerRelayIlluminatorPowerIlluminatorRS-485

Strona 9 - 2 Accessing the Camera

Day/Night Functionality AW00101507000102 Basler IP Fixed Dome Cameras

Strona 10

AW00101507000 Real-Time Trigger FunctionalityBasler IP Fixed Dome Cameras 1037 Real-Time Trigger Functionality7.1 Introduction The camera normally

Strona 11 - 3 Configuring the Camera

Real-Time Trigger Functionality AW00101507000104 Basler IP Fixed Dome Cameras1/30 s1/30 s1/30 s1/30 s1/30 sCamera Controlled Capture 1Camera Controlle

Strona 12

AW00101507000 Real-Time Trigger FunctionalityBasler IP Fixed Dome Cameras 105If you take a close look at Figure 19, you will notice that two of the im

Strona 13 - Fig. 3: Camera Block Diagram

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 73 Configuring the CameraThis section describes how to configure your camera. It is i

Strona 14 - Camera Parameters

Real-Time Trigger Functionality AW00101507000106 Basler IP Fixed Dome Cameras7.2 Enabling and Using Real-Time TriggeringTo enable real-time triggering

Strona 15

AW00101507000 Real-Time Trigger FunctionalityBasler IP Fixed Dome Cameras 1077.3 Real-Time Triggering Impact on StreamsWhen you are setting the Stream

Strona 16 - Autofocus functionality

Real-Time Trigger Functionality AW00101507000108 Basler IP Fixed Dome Cameras

Strona 17 -  contaminated lens

AW00101507000 Technical SpecificationsBasler IP Fixed Dome Cameras 1098 Technical Specifications8.1 BIP2-D1000c-dn and BIP2-D1300c-dnSpecification BIP

Strona 18 - 3.3 Image Control Parameters

Technical Specifications AW00101507000110 Basler IP Fixed Dome CamerasAlarm Management Ring buffer for pre and post alarm imagesMicroSDHC card slot fo

Strona 19

AW00101507000 Technical SpecificationsBasler IP Fixed Dome Cameras 1118.2 BIP2-D1920c-dn (Outdoor)/(Outdoor, AF) and BIP2-D1920c-dn (Indoor)/(Indoor,

Strona 20 - 3.3.2 Appearance Tab

Technical Specifications AW00101507000112 Basler IP Fixed Dome CamerasAlarm Management Ring buffer for pre and post alarm imagesMicroSDHC card slot fo

Strona 21 - 3.3.3 Day/Night Tab

AW00101507000 Technical SpecificationsBasler IP Fixed Dome Cameras 113Standards DIN EN 50130-4, FCC Class A, CE, RoHS, ONVIFHousing 148 mm x 122 mm (

Strona 22

Technical Specifications AW00101507000114 Basler IP Fixed Dome Cameras8.3 DimensionsFig. 20: Dimensions in mm (inches)

Strona 23 - 3.3.4 Focus Tab

AW00101507000 Software License InformationBasler IP Fixed Dome Cameras 115Appendix A Software License InformationMPEG-4:THIS PRODUCT IS LICENSED UNDER

Strona 24 - 3.4 Streaming Parameters

Configuring the Camera AW001015070008 Basler IP Fixed Dome CamerasControls, Streaming, Motion Detection, Alarm Handling, etc. Except for the Streaming

Strona 25 - 3.4.1 Global Tab

Software License Information AW00101507000116 Basler IP Fixed Dome CamerasOther SoftwareThe camera contains software originating from a variety of thi

Strona 26

AW00101507000 Revision HistoryBasler IP Fixed Dome Cameras 117Revision HistoryDoc. ID Number Date ChangesAW00101501000 16 Jun 2011 Initial release of

Strona 27

Revision History AW00101507000118 Basler IP Fixed Dome CamerasAW00101505000 31 Jul 2012 Added the description of the new Audio Encoder Type parameter

Strona 28 -  Motion Mask Editor

AW00101507000 Revision HistoryBasler IP Fixed Dome Cameras 119AW00101506000 3 Apr 2014 Updated the Support contact information in the Contacting Basle

Strona 29

Revision History AW00101507000120 Basler IP Fixed Dome Cameras(continued from previous page)Removed the NTP parameter in the System parameter group.Ad

Strona 30

AW00101507000 IndexBasler IP Fixed Dome Cameras 121IndexAadding a user...70alarm actions...

Strona 31

Index AW00101507000122 Basler IP Fixed Dome Camerasframe rateimage capture ...8stream...

Strona 32

AW00101507000 IndexBasler IP Fixed Dome Cameras 123motion threshold parameter ...42MPEG4...

Strona 33 - Mask Editor Tools

Index AW00101507000124 Basler IP Fixed Dome Camerasstop button ...11storage location parameter ...

Strona 34 - 3.4.2 Stream Tabs

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 9Fig. 3: Camera Block DiagramImagingSensorStream 0EncoderCameraGlobalParameters(Senso

Strona 35

Configuring the Camera AW0010150700010 Basler IP Fixed Dome Cameras3.2 Accessing the Configuration Tools and Camera Parameters 1. If you have not alre

Strona 36

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 113. A Camera Configuration menu will open on the left side of the client as shown be

Strona 37

Configuring the Camera AW0010150700012 Basler IP Fixed Dome Camerasrefresh rate. Opening and closing parameter groups or switching from one tab to ano

Strona 38

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 13 low optical contrast (e.g. a white wall) contaminated lensThe focus can be readj

Strona 39

Configuring the Camera AW0010150700014 Basler IP Fixed Dome Cameras3.3 Image Control ParametersThe parameters in the Image Controls group control the

Strona 40

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 15Exposure Offset - Is used to customize the operation of the camera’s automatic cont

Strona 41

Contacting Basler Support WorldwideEurope and the Middle East:Basler AG Phone: +49 4102 463 515An der Strusbek 60 - 62 Fax: +49 4102 463 59922926 Ahre

Strona 42

Configuring the Camera AW0010150700016 Basler IP Fixed Dome CamerasGain Limit - When automatic gain control is enabled (see Exposure Mode above), the

Strona 43

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 17 Fluorescent I = The camera will automatically change the white balance settings s

Strona 44

Configuring the Camera AW0010150700018 Basler IP Fixed Dome CamerasIR Filter State - Indicates the current state of the camera’s IR-cut filter.  Nigh

Strona 45

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 193.3.4 Focus Tab Note: The focus tab is only available on camera models with autofoc

Strona 46

Configuring the Camera AW0010150700020 Basler IP Fixed Dome Cameras3.4 Streaming ParametersThe parameters in the Streaming group are used to control t

Strona 47 - 3.6 Alarm Handling Parameters

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 213.4.1 Global TabThe parameters on the Global tab control the way that the camera’s

Strona 48

Configuring the Camera AW0010150700022 Basler IP Fixed Dome CamerasSensor AOI Left - As shown in Figure 4 on page 21, sets the left offset (in pixels)

Strona 49 - 3.6.2 Alarm Buffers Section

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 23Test Image Mode - Enables or disables the camera’s test image feature. When the tes

Strona 50 - 3.6.3 Alarm Actions Section

Configuring the Camera AW0010150700024 Basler IP Fixed Dome CamerasSensor AOI Editor - Whenever the Global tab is selected, the Sensor AOI Editor tab

Strona 51 - HTTP Tab

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 25White Balance Mask - Click the White Balance Mask button to open the White Balance

Strona 52

AW00101507000 Table of ContentsBasler IP Fixed Dome Cameras iTable of Contents1 Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 53

Configuring the Camera AW0010150700026 Basler IP Fixed Dome CamerasAuto Brightness Mask - Click the Auto Brightness Mask button to open the Auto Brigh

Strona 54

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 27Privacy Mask - Click the Privacy Mask button to open the Privacy Mask Editor as sho

Strona 55 - 3.7 Live Recording Parameters

Configuring the Camera AW0010150700028 Basler IP Fixed Dome CamerasMotion Mask - Click the Motion Mask button to open the Motion Mask Editor as shown

Strona 56 - 3.7.2 SD Card Tab

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 29Mask Editor Tools To apply a mask, all editors use the same tools. These are arran

Strona 57 - 3.7.3 FTP Tab

Configuring the Camera AW0010150700030 Basler IP Fixed Dome Cameras3.4.2 Stream TabsThe parameters on the Stream 0 tab, Stream 1 tab, and Stream 2 tab

Strona 58 - 3.8 Network Parameters

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 31Encoder Type - Sets the video encoder type for the stream.  Off = The video str

Strona 59 - 3.8.2 RTSP Tab

Configuring the Camera AW0010150700032 Basler IP Fixed Dome CamerasEncoder Type - (continued from previous page) YUV (RT triggered) = The camera will

Strona 60 - 3.8.4 I/O Tab

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 33If the Encoder Mode parameter is set to Capped VBR, you can also set the desired qu

Strona 61 - 3.8.6 ONVIF Tab

Configuring the Camera AW0010150700034 Basler IP Fixed Dome CamerasOutput Size - Lets you select from a list of standard image sizes. When you select

Strona 62 - 3.9 Input / Output Parameters

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 35Stream AOI Left - As shown in Figure 5 on page 30, sets the left offset (in pixels)

Strona 63

Table of Contents AW00101507000ii Basler IP Fixed Dome CamerasAppendix A Software License Information . . . . . . . . . . . . . . . . . . . . . . . .

Strona 64 - Global Shutter

Configuring the Camera AW0010150700036 Basler IP Fixed Dome CamerasGOP Length [ms] - If the Encoder Type parameter is set to H.264 or MPEG4, then the

Strona 65 - Rolling Shutter

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 37 Overlay Text - Sets the text that will appear in the text overlay. You can enter

Strona 66 - Fig. 8: Flash Window Signal

Configuring the Camera AW0010150700038 Basler IP Fixed Dome CamerasOverlay Position - Sets the position of the text overlay.  Top Left = Place the

Strona 67 - BIP2 - D1920c 29.479166 µs

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 39+Framecount - Click the +Framecount button to quickly enter the $counter$ expressio

Strona 68 - Frame Acquisition N+2

Configuring the Camera AW0010150700040 Basler IP Fixed Dome CamerasStream AOI Editor - Whenever a stream tab is selected, a Stream AOI Editor screen w

Strona 69 - 3.9.2 Serial I/O Tab

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 413.5 Motion Detection ParametersThe parameters in the Motion Detection group are use

Strona 70 - 3.10 User Parameters

Configuring the Camera AW0010150700042 Basler IP Fixed Dome CamerasMotion Threshold - Sets a threshold for motion detection. If the number of changed

Strona 71

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 433.6 Alarm Handling ParametersThe parameters in the Alarm Handling group are used to

Strona 72 - 3.10.3 Managing Users

Configuring the Camera AW0010150700044 Basler IP Fixed Dome CamerasMotion Tab Cyclic Tab Heartbeat Missing Tab Source Enable - Check the Source Enabl

Strona 73

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 453.6.2 Alarm Buffers SectionEach video stream can have an alarm buffer. Normally, th

Strona 74 - To Delete an Existing User

AW00101507000 IntroductionBasler IP Fixed Dome Cameras 11 Introduction1.1 About this DocumentApplicabilityThis document applies to cameras that have t

Strona 75

Configuring the Camera AW0010150700046 Basler IP Fixed Dome Cameras3.6.3 Alarm Actions Section The alarm actions section of the alarm handling paramet

Strona 76

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 47Email Password - Enter a password for authentication on the SMTP server. Up to 29 c

Strona 77 - 3.11 Audio Parameters

Configuring the Camera AW0010150700048 Basler IP Fixed Dome CamerasMotionLevel_0=<motion level> = current motion level (number of changed pixels

Strona 78 - 3.12 System Parameters

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 49FTP Password - Enter a password for authentication on the FTP server. Up to 29 char

Strona 79

Configuring the Camera AW0010150700050 Basler IP Fixed Dome CamerasSD Card Tab Include Stream - Check the Include Stream box to save video files

Strona 80 - 3.12.3 Management Tab

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 513.7 Live Recording ParametersThe parameters in the Live Recording group are used to

Strona 81

Configuring the Camera AW0010150700052 Basler IP Fixed Dome CamerasStorage Location - Sets the location where the live stream should be saved.  SD Ca

Strona 82

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 53file structure for the SD card. The browser functionality will allow you to navigat

Strona 83

Configuring the Camera AW0010150700054 Basler IP Fixed Dome Cameras3.8 Network ParametersThe parameters in the Network group are used to set the camer

Strona 84

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 55Search Domain - Sets the domain names the camera will use for resolving non-fully q

Strona 85

Introduction AW001015070002 Basler IP Fixed Dome Cameras1.2 Precautions WEEE Directive The European Union has enacted Directive 2002/96/EC on Waste El

Strona 86

Configuring the Camera AW0010150700056 Basler IP Fixed Dome CamerasCommit - Click the Commit button to save any changes you have made to the RTSP sett

Strona 87 - 4 Factory Default Button

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 573.8.5 SNMP Tab 3.8.6 ONVIF Tab SNMP Enable - Check the SNMP Enable box to enable th

Strona 88

Configuring the Camera AW0010150700058 Basler IP Fixed Dome Cameras3.9 Input / Output ParametersThe parameters in the Input/Output group are used to c

Strona 89 - Connector

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 59 External Trigger = The external trigger function is used to control the exposure

Strona 90 - (Present on outdoor

Configuring the Camera AW0010150700060 Basler IP Fixed Dome Camerassensor information in the specification tables in Section 8 on page 109. For genera

Strona 91

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 61Rolling Shutter On cameras equipped with a rolling shutter, the pixel lines are exp

Strona 92

Configuring the Camera AW0010150700062 Basler IP Fixed Dome CamerasUsing the Flash Window (Rolling Shutter) To provide the best-possible lighting cond

Strona 93

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 63You can calculate when the flash window will open (i.e., the time from the frame tr

Strona 94

Configuring the Camera AW0010150700064 Basler IP Fixed Dome CamerasUsing Exposure Active (Rolling Shutter) When the Strobe Mode parameter is set to &q

Strona 95 - 5.2 The RS-485 Terminal Block

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 653.9.2 Serial I/O Tab The parameters on the Serial I/O tab are used to configure the

Strona 96 - 5.3 The Audio Connector

AW00101507000 IntroductionBasler IP Fixed Dome Cameras 31.3 Overview RJ-45 Network / PoE - Provides a 10/100 Ethernet connection and can be used to c

Strona 97 - 5.3.2 Audio Y-Cable

Configuring the Camera AW0010150700066 Basler IP Fixed Dome Cameras3.10 User ParametersThe parameters in the User group are used to manage user authen

Strona 98 - 5.3.3 Audio Schematic

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 673.10.2 Logging In and Logging OutOnce you have logged into the camera, a Logged in:

Strona 99 - 6 Day/Night Functionality

Configuring the Camera AW0010150700068 Basler IP Fixed Dome Cameras3.10.3 Managing Users To manage users, you must be logged into the camera as an ad

Strona 100

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 69The available user levels are described in Table 2.User Level MeaningAdministrator

Strona 101

Configuring the Camera AW0010150700070 Basler IP Fixed Dome CamerasTo Add a New User 1. Click the New User button on the User Management tab. A User

Strona 102

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 713. An Are you sure message window will open. Click the Ye s button.4. A Success mes

Strona 103

Configuring the Camera AW0010150700072 Basler IP Fixed Dome CamerasTo Change an Existing User’s User Level 1. On the User Management tab, click on th

Strona 104

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 733.11 Audio ParametersThe parameters in the Audio group are used to configure the ca

Strona 105

Configuring the Camera AW0010150700074 Basler IP Fixed Dome Cameras3.12 System ParametersThe parameters in the System group provide some basic informa

Strona 106

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 75 Time Zone Description - Sets the time zone. Select the correct time zone for the c

Strona 107 - Functionality

Introduction AW001015070004 Basler IP Fixed Dome Cameras Status Indicator LEDs - The green LED indicates the network connection speed. Off means the

Strona 108 - Real-time

Configuring the Camera AW0010150700076 Basler IP Fixed Dome CamerasNTP Server Source - Determines the way the NTP server parameter will be set.  DHCP

Strona 109

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 77Config Management - Use the Config Management button to save the camera’s current p

Strona 110 - Triggering

Configuring the Camera AW0010150700078 Basler IP Fixed Dome Cameras4. In the Save As dialog box, select a location where the file will be saved, enter

Strona 111

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 79Start Firmware Update - Occasionally, firmware updates may be made available to the

Strona 112

Configuring the Camera AW0010150700080 Basler IP Fixed Dome Cameras2. Click the OK button in the Start Firmware Upload dialog box.A web page will open

Strona 113 - 8 Technical Specifications

AW00101507000 Configuring the CameraBasler IP Fixed Dome Cameras 814. Make sure that the firmware is correct and then click the Confirm Update button.

Strona 114

Configuring the Camera AW0010150700082 Basler IP Fixed Dome Cameras

Strona 115

AW00101507000 Factory Default ButtonBasler IP Fixed Dome Cameras 834 Factory Default ButtonA factory defaults button is available on the side of the c

Strona 116

Factory Default Button AW0010150700084 Basler IP Fixed Dome Cameras

Strona 117 - 5.83" x 4.8")

AW00101507000 Terminal Blocks and Audio ConnectorBasler IP Fixed Dome Cameras 855 Terminal Blocks and Audio Connector5.1 The Main Terminal BlockThe te

Strona 118 - 8.3 Dimensions

AW00101507000 Accessing the CameraBasler IP Fixed Dome Cameras 52 Accessing the CameraThe following instructions assume that you have used the Basler

Strona 119 - AVC (H.264)

Terminal Blocks and Audio Connector AW0010150700086 Basler IP Fixed Dome CamerasThe assignments for the wire fixing holes in the main terminal block a

Strona 120 - Other Software

AW00101507000 Terminal Blocks and Audio ConnectorBasler IP Fixed Dome Cameras 87The functionality of each wire fixing hole in the main terminal block

Strona 121 - Revision History

Terminal Blocks and Audio Connector AW0010150700088 Basler IP Fixed Dome CamerasHole Name: I/O-0, I/O-1Function: I/O port 0 and I/O port 1 respectivel

Strona 122

AW00101507000 Terminal Blocks and Audio ConnectorBasler IP Fixed Dome Cameras 89Hole Name: DC OutFunction: DC Out supplies unregulated +5.6 VDC and ca

Strona 123

Terminal Blocks and Audio Connector AW0010150700090 Basler IP Fixed Dome CamerasFig. 11: I/O, Alternate Power, and RS-485 SchematicRS-485 Gnd(isolat

Strona 124

AW00101507000 Terminal Blocks and Audio ConnectorBasler IP Fixed Dome Cameras 915.2 The RS-485 Terminal BlockThe 3-hole terminal block on the right si

Strona 125 - AW00101507000 Index

Terminal Blocks and Audio Connector AW0010150700092 Basler IP Fixed Dome Cameras5.3 The Audio Connector5.3.1 Audio Connector Type and Pin AssignmentsT

Strona 126 - Index AW00101507000

AW00101507000 Terminal Blocks and Audio ConnectorBasler IP Fixed Dome Cameras 935.3.2 Audio Y-CableA Y-cable for use with the audio connector is shipp

Strona 127

Terminal Blocks and Audio Connector AW0010150700094 Basler IP Fixed Dome Cameras5.3.3 Audio SchematicA schematic for mic-in / line-in and for line-out

Strona 128

AW00101507000 Day/Night FunctionalityBasler IP Fixed Dome Cameras 956 Day/Night Functionality6.1 IntroductionBasler IP Fixed Dome Cameras are equipped

Komentarze do niniejszej Instrukcji

Brak uwag