AW00101507000 Terminal Blocks and Audio Connector
Basler IP Fixed Dome Cameras 85
5 Terminal Blocks and Audio
Connector
5.1 The Main Terminal Block
The terminal block on the front of the camera base can be used to:
provide alternate power to the camera when PoE is not used
(this functionality is available on outdoor dome cameras only)
access the camera’s I/O ports
power a small DC device such as a relay
limit the camera’s power consumption by disabling the camera’s heater
NOTICE
Do not apply AC voltages or voltages outside of the specifications to the main terminal block.
1. Apply only DC voltages. Applying AC voltages can severely damage the camera.
2. Make sure that the voltages are within the limits specified in Table 3 on page 87. Applying
voltages outside of the specifications can severely damage the camera.
NOTICE
Always switch off camera power before making or breaking connections at the main terminal
block.