Terminal Blocks and Audio Connector AW00101507000
86 Basler IP Fixed Dome Cameras
The assignments for the wire fixing holes in the main terminal block are as shown below and
explained in Table 3 on page 87.
Fig. 10: Main Terminal Block
The main terminal block is a push-in type of connector. Either solid or stranded wires can be
inserted into the wire fixing holes in the terminal block. A wire can be removed from a fixing hole by
pressing the release tab above the hole and pulling on the wire.
Wires inserted into the fixing holes must have a minimum cross section of 0.2 mm
2
(AWG 24) and
a maximum cross section of 1.5 mm
2
(AWG 16).
8 mm (5/16") of insulation should be stripped from the end of a wire before it is inserted into a fixing
hole.
Basler recommends that connections to the I/O ports be made with shielded cable
and that the cable shields be connected to ground. If you are unable to connect
the cable shields to ground or if you use unshielded cable, the maximum length of
the I/O port connections is limited to 10 m to avoid electromagnetic interference.